Skip to content
Technical & commercial enquiries: sales@rssechem.com Certificate of analysis issued per lot · Worldwide shipping
Register Request a quote & Contact us

What a synthesis laboratory needs before it can quote

Sourcing & supplier choice Published By RSSE Technical Team · Reviewed by RSSE Quality Unit

Custom work is quoted against a specification. If the specification is a name in an email, the quotation is a guess with a number attached.

On this page

The structure, with stereochemistry drawn

A two-dimensional skeleton leaves the stereocentres to the reader. Draw them, or state the configuration in words. The same applies to double bond geometry and to ring conformations where a single isomer is wanted. A synthesis aimed at the wrong diastereomer costs a campaign and produces material nobody can use.

Quantity, form and purity target

State the mass you need, not the mass you hope to need. Scale changes the route: a milligram-scale purification and a hundred-gram campaign do not share a method. Say whether a solid is required or a solution will do, and give the purity target as a number with the method that will measure it. A target of "as pure as possible" cannot be tested against.

What the material has to support

Identification only, or quantitative use with an assigned content. Quantitative use brings an extra set of requirements: a value with an uncertainty, a documented assignment route and a stability statement. Say which, because it changes the analytical work that follows the synthesis.

If the compound is intended for a regulatory filing, say so at the enquiry stage. The documentation package is designed differently when it will be read by an assessor.

Route preferences and constraints

Some customers have a route in mind, or a route they must avoid because of a patent position or an internal safety rule. Some have an intermediate available that would shorten the work. Passing that on saves a step and sometimes the whole campaign.

Confidentiality arrangements belong here too, not after the structure has been sent.

The analytical package that comes with the material

Ask what will be delivered alongside the compound. A certificate stating identity and content is the minimum; the data behind those statements is what makes them usable. Proton and carbon NMR, a high-resolution mass measurement, a chromatogram at a stated wavelength and a quantitative result with its method form the usual set.

Say in advance if you need the raw data rather than the summary. Recovering spectra after a project closes is harder than asking for them at the start, and a filing often needs the original files rather than a table of numbers.

Agree the acceptance criteria before the work begins. A purity figure delivered without an agreed method can be argued about indefinitely, and the argument is more expensive than the analysis.

What we can supply

Custom items quoted against a structure, with the delivered material carrying a lot-specific certificate stating identity evidence and assigned content. Where the compound corresponds to a pharmacopoeial definition, the item is described against that definition so the correspondence is explicit rather than assumed. Structures, formulae and exact masses are published for catalogue items, and custom items are described the same way.

Frequently asked

How detailed does the structure need to be?
Detailed enough that two chemists would draw the same molecule, including stereochemistry and double bond geometry.
Can a custom item be supplied as a solution?
Yes, and for unstable compounds it is often the better form. State the solvent you can work with.
Does a custom standard come with an assigned content?
It can, if that is specified at the enquiry stage. Identification-only material is cheaper and cannot be used for quantification.

Sources and further reading

Every document below is published by the body that owns it; none of them is a summary written by us. Accessed 2026-11-24.

Send us a CAS number

Availability, documentation and lead time — answered by the people who handle the batch, not a ticket queue.

Request a quote sales@rssechem.com

How to read a certificate of analysis Field by field: identity, purity, content basis, the retest date, and the questions worth asking a supplier before you file the document.How to choose a reference standard supplier A practical checklist for evaluating reference standard suppliers on documentation, traceability, lot consistency, logistics and technical support.Stable isotope-labelled standards and when to use them When labelled internal standards earn their place in an LC-MS or GC-MS method, what to specify when ordering, and the traps in quantitative work.Nitrosamine and NDSRI standards: what to test for and what to buy The difference between small nitrosamines and NDSRIs, what a laboratory needs as a standard for each, and how to specify one so the result stands up to review.What is an impurity reference standard? What the term means, how it differs from a pharmacopoeial standard and a working standard, what the documentation has to state, and how to pick the right form and purity basis.ICH M7 in practice: classifying mutagenic impurities How the five-class hazard assessment works, what the 1.5 microgram default really covers, and how the four control options decide which standards you buy.qNMR vs mass balance: how purity is really assigned Two certificates, one compound, two purity values. What mass balance and qNMR each measure, why the figures differ, and how the basis changes the number.Elemental impurities: from a PDE to a limit you can measure How a permitted daily exposure becomes a concentration limit, why the dose moves the number, and what an elemental impurity specification must state.Salt, hydrate and free base: converting content so the numbers reconcile How to move content and impurity values between as-is, anhydrous and free-base bases, in what order, and why the basis can turn a pass into a fail.Forced degradation study design: how far to push each stressor How to set stressor strength, read a kinetics screen, judge mass balance and catch over-degradation before it wastes a method development cycle.Analytical method transfer: acceptance criteria you can defend Four transfer routes, criteria built from the method's own precision, and the standard's assigned content that shifts every result by a fixed amount.Chiral and stereoisomeric impurity standards Enantiomer, diastereomer, epimer, E/Z isomer: four different standards and four different questions. What each has to state before it can control a method.Reference standard, analytical standard, CRM: what the words mean Four labels appear on the same vial in different catalogues. They are not synonyms, and the difference decides what you may claim in a report.Peptide reference standards: what changes when the analyte is a chain Deletion sequences, epimers, pyroglutamate, deamidation, counter-ion and water: why a peptide standard needs a different certificate from a small molecule.Cleaning validation residue limits: where the number comes from How a residue limit is derived from the dose, from 10 ppm and from a health-based PDE, and what the swab method and its standard must be able to reach.Cold chain and stability of reference standards: what transport and receipt checks protect Storage regimes, stability budgets and mean kinetic temperature, plus the receipt checks that decide whether a standard still supports its certificate.Impurity profile comparison: what a reference standard proves, and what it does not How reporting, identification and qualification thresholds set the scope of an impurity profile comparison, and where a standard stops proving anything.Weighing a reference standard: minimum weight and moisture How the 0.10% repeatability rule sets a minimum weight, why a hygroscopic standard is used as is, and which figures belong on the worksheet.Standard solution stability: how long a prepared standard can be used How to set a hold time for a standard solution: two baselines, six failure modes, a defensible study design and criteria fixed before the data arrive.Reporting, identification and qualification thresholds by dose How the 0.05, 0.10 and 0.15 per cent thresholds are banded by dose, where the milligram cap takes over, and what each limit forces you to test.USP 233 in practice: the J value and the four preparation routes How chapter 233 turns a limit into a J value, which of four preparation routes to use, and the acceptance criteria a method must meet before routine use.Building an uncertainty budget for a standard solution A worked budget for a 1 mg/mL standard solution: weighing, assigned value and volume, the correlation trap, and when k = 2 understates coverage.When the reference standard is the suspect in an OOS result How to test whether a reference standard caused an out-of-specification result, and how to separate a changed material from a misapplied assigned value.Two certificates for one compound: reconciling them field by field How to compare two certificates for the same compound: identity, measurand, basis, assignment, uncertainty, and the order that makes the numbers comparable.How much evidence identifies an unknown impurity How much evidence actually identifies an unknown impurity: formula searches, isotope arithmetic, the limits of fragments, and what a reference standard adds.Relative response factors: what the ratio does to a reported impurity What a relative response factor does to a reported impurity result, why the direction of the bias decides whether it can be waived, and how to measure it.Nitroso impurity numbering: why 3 is not the same compound twice A catalogue number is not a chemical name. How to specify a nitroso impurity by position and structure, before a purchase turns into the wrong isomer.How nitroso impurities form: the two partners and where they meet Nitrosation needs an amine and a nitrosating species in the same place at once. The practical question is where that happens in a process or a formulation.Testing for nitroso impurities: detectors, artefacts and proof Why a standard HPLC-UV method cannot carry a nitrosamine limit, which detectors fit, and what a spiked standard adds that a retention time does not.What a nitroso impurity certificate has to state Identity, assigned content and stability are three separate claims. On a reactive impurity they cannot be copied from the template used for a stable solid.qNMR sample preparation: the steps that decide the number Weighing, solvent, internal standard and acquisition parameters. Where accuracy is won or lost before the first scan is acquired.qNMR calculation: one worked example, every term explained Integral ratio, proton counts, molar masses and the purity of the standard. Where each term comes from, and how a small weighing error moves the answer.The qNMR balance check: reconciling three purity numbers Three numbers describe one powder. When they disagree, the gap is the information: water, residual solvent, inorganic residue or a detector that cannot see.Choosing a qNMR internal standard: spectrum, solubility, stability A single sharp signal is the entry requirement. Solubility, volatility and hygroscopicity decide whether the number survives the weighing.SDS and certificate of analysis: which document answers what The safety data sheet describes hazards and handling. The certificate describes one lot. Audits, shipping papers and storage decisions need the right one.Safety data sheets for stable isotope compounds Stable isotopes are not radioactive, and their SDS should not read as if they were. What changes on the document, and what to check before filing it.What to put in an impurity standard enquiry Most first enquiries cannot be quoted because one field is missing. A short list of what a supplier needs, and why each item changes the answer.Which impurity standards a new API needs first Route-based suspects, degradation products and the ones a method cannot be validated without. A sequence that avoids buying standards twice.System suitability, calibration and reference standards in HPLC Suitability checks the system, calibration checks the response, a standard anchors identity. Mixing them is how a method passes and a result is wrong.GC-MS standards for volatile and semi-volatile impurities Volatility, thermal stability and derivatisation decide the route. What changes in the standard when the detector is a mass spectrometer.Deuterium or carbon-13: choosing the label for the job Cost, exchange, isotope effects and mass resolution. The label choice follows from whether the material is an MS internal standard or an NMR reference.Internal standard correction in ICP-OES and ICP-MS Drift, matrix effects and transport efficiency are different problems. One added element corrects some of them, and the wrong choice hides the rest.Pharmacopoeial impurity letters: what A, B and C actually mean Letters are assigned per monograph and can be reassigned when the text is revised. How to map a letter to a structure before you buy it.In-house impurity codes and how to make them portable Company numbering schemes are not transferable. How to convert an internal designation into a specification a supplier can quote against.Metabolite standards: what to specify beyond the structure Hydroxylation position, conjugation, stability in solution and the difference between a bioanalytical standard and a drug substance impurity.